Installation Guide UK/EU

Installation Guide

Written by Adam Vergette

1. Before You Start

Make sure you have the following to hand:

  • Your IKEA kitchen plan

  • Your Plykea visual

  • Your packing list

  • IKEA's installation guide

2. Understanding Your Delivery

Each item on your packing list is marked with a letter, which also appears on the corresponding package. Use this to identify your items and check your delivery.

Each panel is engraved on the reverse with a number that corresponds to your IKEA plan.

Drawer fronts are labelled sequentially (1A, 1B, 1C), from bottom to top. Follow this order to maintain grain continuity.

Key:

  • CP = Cover Panel

  • FP = Filler Panel

  • SP = Spacer Panel

  • TP = Top Panel

  • U = Underside Panel

  • BK = Back Panel

3. Quality Control and Storage

All items are checked before leaving our workshop.

  • Keep protective film on laminate fronts until installation. If storing for an extended period, remove it to prevent sticky residue.

  • Store all fronts flat and away from direct sunlight.

  • Keep items on a stable surface until installation.

We recommend arranging delivery once building work is complete and the site is clean to minimise the risk of damage.

4. Hinges and Drawer Runners

Hinges and drawer runners should be purchased from IKEA.

  • Standard-sized fronts come pre-drilled.

  • Custom-sized fronts require 35mm hinge cups to be drilled on-site.

  • Plinth clips are included with your order.

5. Cover Panels and Worktops

Sizes

  • Cover panels are supplied at 67cm deep (IKEA standard: 62cm).

  • Worktops are supplied at 70cm deep.

The additional depth allows for service voids, installation adjustments and worktop overhangs. Check your order sheet for exact dimensions. Excess material can be trimmed on-site for a precise fit.

Checking your panels

Location numbers are discreetly engraved on the back of panels. Make sure these are not visible once installed.

If a label differs from your order sheet but the panel fits correctly, it may be a labelling error. Please let Plykea know.

Veneer panels

To reduce waste, most wood-veneered cover panels are fully lacquered on the front only. The reverse has two engraved lines and is lacquered up to these lines.

Back and filler panels are also finished on one side only, with an engraved X marking the reverse. Back panels are used to finish exposed cabinet backs, particularly on islands and peninsulas.

Cutting panels

For Fenix, Formica and Arpa panels:

  • Apply masking tape along the cut line and use a sacrificial board underneath.

  • Use a sharp, fine-cut blade with a plunge saw.

  • For awkward cuts, use a fine-toothed jigsaw blade suitable for metal or plastic.

Finishing cut edges

Sand with 120-grit, followed by 320-grit sandpaper. Apply Osmo Polyx Oil Glossy 3011 and wipe off after 1–2 minutes. Lightly sand again with 320 grit, removing all excess oil before it dries.

Wall cabinets and islands

Cover panels fitted underneath wall cabinets or to the back of islands are supplied slightly oversized. Your installer should trim them on-site for an exact fit.

6. Spacer Panels

Installation

Fit spacer panels while assembling the carcasses.

  • Clamp in place and screw from inside the carcass using the pre-drilled holes.

  • Each pair includes one front and one rear spacer to maintain even spacing and prevent twisting.

  • Only the front spacer is finished, so make sure it is fitted in the correct position.

Spacer depth

To ensure doors and drawers sit flush when closed, spacers should project beyond the carcass by:

  • Ash / Oak / Walnut / Maple / Beech / Sapele / Douglas Fir: 21mm (19mm front + 2mm bumpons).

  • Formica / Arpa / Fenix: 22mm (20mm front + 2mm bumpons).

Wall cabinets

If you are not fitting cover panels underneath wall cabinets, the gaps between carcasses will need filling.

Mitre the spacer panels at 45° and join them to create an L shape. Any remaining off-cut can be fixed near the back for additional support.

Framed finish

For a full plywood look, we can supply horizontal spacers or top panels to create a framed finish across the front and between carcasses. These are supplied slightly oversized and should be trimmed on-site.

When using these panels:

  • Tower and wall unit cover panels should extend 20mm above the cabinet.

  • For tower units, include the top panel when measuring and cutting cover panels.

  • Wall unit cover panels are supplied at finished length and should not be trimmed.

The top piece is 75mm deep, and the extended cover panel will conceal it.

7. Additional Installation Guides

For further guidance, please see our separate articles:

  • Non-IKEA Dishwashers: Using Non-IKEA Integrated Dishwashers and Appliances.

  • Worktops: How Do I Join My Worktops?

Did this answer your question?